Aquifers and Hydraulic Head
A deep well can overflow while a shallower one stays quiet.
Imagine two boreholes tapped into the same sand bed. When you open the well on the hillside, the water sits several metres below its rim. Open the one in the valley and water comes out without a pump.
What changed if the water came from the same bed?
Groundwater Occurrence
The ground beneath your feet need not hide a lake. Most groundwater occupies connected pores in sediment or openings such as fractures in rock.
An aquifer is a body of saturated geological material sufficiently permeable to yield useful quantities of groundwater to wells or springs. An aquitard is a geological unit that transmits water much less readily than adjacent aquifers. It can still leak.
In an unconfined aquifer, the upper boundary is the water table. At the water table, water pressure equals atmospheric pressure. Water can be drawn into pores just above it by capillary forces, but its pressure there is below atmospheric.
In a confined aquifer, a less permeable layer overlies the water-bearing material and water can rise above the aquifer roof in an isolated well.
Some beds are only partly confined because the cover leaks.
Measurement of Hydraulic Head
The height water can rise tells you how much mechanical energy it has to move. Hydraulic head is mechanical energy per unit weight of water, expressed as a height relative to a reference elevation.
Groundwater moves slowly enough that velocity head is normally negligible. With gauge pressure (measured relative to air pressure), the head is elevation head plus pressure head.
A datum is the vertical reference from which you measure elevations. In a static, non-flowing, vented well open to a single interval, the standing water level measures head in that interval. A potentiometric surface is a map of those heads for the chosen aquifer, not necessarily the location of a free-water surface underground.
Hydraulic Head
is elevation above the datum in m; is gauge pressure in Pa; is water density and is gravitational acceleration. is a height in m. At the open water surface in the well, .
Worked example
Calculation of Head From a Static Water Level
You survey the top of a casing at 280 m on a shared datum. The water surface is 15 m below the measuring mark at the top.
- 1 Identify the Measuring Point
Use 280 m, the elevation of the point from which you actually measured. Do not substitute the local ground elevation.
Pause & think
The roof of a confined aquifer is at 180 m, head is 205 m and the well outlet is at 212 m, all on the same datum. What does water do in the open well?
To decide whether a confined well can flow, compare its static head with the elevation of the outlet, not with the depth of the screen.
📌 If you remember nothing else…
- Groundwater occupies geological openings; aquifers yield it, whereas aquitards impede its movement.
- The water table is a pressure boundary; a confined potentiometric surface is an imaginary surface of measured heads.
- Use the same datum when you compare two heads or a head and an outlet elevation.
Quick check
Did it land?
Spotted a mistake?